českyEnglishDeutsch
Menu / Activities / Authorized body AO 216 (GO 163)


AUTHORIZED BODY AO 216
Authorisation to perform activities concerning conformity attestation of products under Government Order No. 163/2002 Coll. laying down technical requirements for selected construction products

PAVUS, a.s., is authorised by the Czech Office for Standards, Metrology and Testing (COSMT) under Article 11(1) and Article 20 of Act No. 22/1997 Coll. on technical requirements for products and on amendments to some acts, as amended, to perform the activities concerning conformity attestation of products set forth pursuant to Article 12(1) of the Act in Government Order No. 163/2002 Coll. (“GO163”) laying down technical requirements for selected construction products.

 

The scope of the company’s authorisation is given in COSMT Decision No. 37/2002 of 13 December 2002 for the following products from Annex 2 of Government Order No. 163/2002 Coll.:

  • 1/16 Non load-bearing permanent shuttering kits/systems of concrete construction based on hollow blocks or panels made of b) a combustible insulating material (or a combination of non-combustible and combustible materials) 
  • 2/5 Masonry units with incorporated (a) non-combustible thermal insulating materials placed on a face which may be exposed to fire and with thermal insulating materials inside the element (b) combustible thermal insulating materials placed on a face which may be exposed to fire
  • 5/2 
    • a) Water- and damp-proofing products for roof coverings for uses to which to which fire safety regulations apply and roof single and multi-element waterproofing for uses to which to which fire safety regulations apply 
    • b) Other water- and damp-proofing materials for roof coverings (roof underlays) and waterproofing sheets for roof coverings (roof overlays)
  • 5/6 Roofing tiles, slates, stones, shingles, roof paving, translucent roofing kits (except glass-based kits) including accessories 
    • a) for uses to which fire safety regulations apply
    • b) for uses to which fire safety regulations do not apply
  • 5/7 Factory made sandwich roofing panels
    • a) for uses to which fire safety regulations apply
    • b) for uses to which fire safety regulations do not apply
  • 5/9 External thermal insulation systems 
    • a) for uses to which fire safety regulations apply
  • 5/12 Fire sealing and fire stopping
  • 5/13 Fire protective coatings, claddings and sprayings
  • 6/1 Fire resistant glass 
  • 6/6 
    • a) Wall panels made from glass blocks for fire compartmentation and/or bullet and explosion-resistant 
    • b) Glass blocks and pavement units for uses to which safety in use requirements apply and to which fire safety regulations and thermal insulation and soundproofing requirements apply
  • 8/1 Windows, doors and gates (with or without relevant hardware) for fire compartmentation and escape routes
  • 8/2 Hardware for doors and gates for fire compartmentation and escape routes
  • 8/3 Windows, doors and gates (with or without relevant hardware) to which thermal insulation, soundproofing or safety in use requirements apply (windows and doors only)
  • 8/5 Door frames 
  • 8/6 Rooflights, dormer windows
    • a) for uses to which fire safety regulations apply
    • b) for uses to which fire safety regulations do not apply
  • 9/10 Kits of internal partitions
    • a) for fire compartmentation or for uses to which safety in use requirements apply
    • b) others 
  • 9/11 Structural sealant glazing systems for external walls and roofs
  • 9/12 Curtain walls
    • a) for uses to which fire safety regulations apply 
  • 10/1 
    • a) Prefabricated chimneys (storey height elements), flue liners (elements or blocks), multi-shell chimney (elements or blocks), single walled chimneys blocks, kits of free standing chimneys and attached chimneys, 
    • b) Overpressure chimneys 
  • 10/2 Chimney terminals
  • 10/3 Fire detection/alarm, suppression and fire-fighting, explosion suppression, fire and smoke control products (except explosion suppression products)
  • 10/4 Fire closures excluding products mentioned under item 1, Table 8, Annex 2 of GO163
  • 10/9 Distribution systems of cooling, ventilation and air-conditioning equipment
    • a) for uses to which fire safety regulations apply 
  • 10/11 Fittings, controllers, safety fittings and safety fixtures, alarm systems for liquid leaks, equipment for the prevention of overfilling, expansion equipment, etc. in installations for transport, distribution and storage of liquids, with the exception of water for human consumption
    • a) for uses to which fire safety regulations apply 
    • b) for uses to which fire safety regulations do not apply 
  • 10/14 Control fittings, fittings and safety fixtures, alarm systems for gas and liquid fuel leaks, equipment for overfilling prevention, filters, separators, expansion equipment, etc. in installations for transport, distribution and storage of gas and fuels for supplying building heating and cooling systems from external reservoirs or the last pressure regulating station in the network for building heating/cooling systems
    • a) for uses to which fire safety regulations apply 
    • b) for uses to which fire safety regulations do not apply 
  • 10/16 Fire and evacuation lifts in respect of fire safety. Fire resistant lift-shaft doors
  • 11/5 Panels, panel boards, elements and sections, façade panels, suspended ceilings, suspended frames, wall covering in roll form and clapboards
    • a) for uses to which fire safety requirements or safety in use requirements and/or hygiene requirements apply
  • 11/6 Gypsum products – plasterboards, blocks and ceiling elements with thin laminations, fibrous gypsum boards and composite panels (laminates) including the relevant ancillary products (for fire separating constructions and fire protective linings), for roof timber structures

 

The scope of conformity attestation is defined by the procedures in Articles 3, 5, 6, 7 and 9 stipulated for the individual product families in Annex 2 of the Government Order.